• Facebook
  • Twitter
  • Instagram
  • LinkedIn
  • Rss
631-393-6401
  • 0Shopping Cart
ALA Scientific
  • ALA Scientific
  • Featured Product
  • Products
  • Applications
  • Company
    • Partners
    • Other Links
  • News
  • Contact
    • Contact Information
    • Ordering Information
    • Sales
    • Support
    • Distributors
  • Menu

71000 Automated for Mice and Rats

Add to quote list
This product is already in quote request list
Browse the list
Category: RWD
  • Overview
  • Details
  • Specifications
  • Ordering

Overview

RWD 71000 Automated Stereotaxic Instrument refine the position of mice and rat’s head by computer-control. Atlas integration and intuitive movement control enable high accuracy, high-throughput electrophysiology, and stereotaxic injections. It can make the head of the animal is properly secured in a position that is perfectly horizontal, during in Rodent Stereotaxic Surgery.

Benefits

  • Integrated brain atlas of rats and mice and 3D display can help locate the target brain area quickly and accurately.
    • Computer Control
    • Brain Atlas Integration
    • Intuitive Navigation
  • Automated task program, like skull window program, tissue removal, and multi point program can meet various experimental need.
    • Experiment Planning
    • Avoids Human Errors
    • Define/Store Targets
    • High Throughput
  • Set Bregma with one click, and 1 micron resolution.
    • Bregma Setting
    • Ultra Precise
  • Three control modes, like PC software, Micromanipulator, and keyboard control are available.
    • Convenient
    • Time Saving

Last Updated on January 7, 2021

Details

1. The operating arm moves up and down, left and right, and back and forth within a range of 80mm, with a high-precision screw, running accuracy of 1μm;

2. One-key calibration function, when using for a long time, the computer display position parameters and locator reading deviation, the user can calibrate by one-key;

3. Positioner movement control function, 4 control modes: a. PC terminal software interface arrow control; b. PC end automatically moves to the target coordinate after inputting the target coordinate position; c. The micro-operation platform can precisely control the positioner movement, micro-operation Every 18 ° rotation of the knob performs a displacement of 1 μm; d, keyboard keys control the movement of the locator.

4. The locator movement speed adjustment function, a. The movement speed can be adjusted by inputting the movement speed at the corresponding positions of the three axes on the PC software interface. Among them, AP axis and ML axis can be selected from 5 movement speeds: 2.00 mm/s、00 mm/s、0.50 mm/s、0.20 mm/s 、0.10 mm/s, 8 kinds of moving speed of DV axis can be selected 2.00 mm/s 、1.00 mm/s、0.50 mm/s、0.20 mm/s 、0.10 mm/s、0.05 mm/s、0.01 mm/s、0.005 mm/s、0.001 mm/s; b. At the micro-operation end, the movement speed of the three axes can be uniformly adjusted by a certain step through the buttons;

5. Set the Bregma / Lambda site with one click. When users use the locator to reach the Bregma / Lambda site, they can mark. One-click to set the Bregma / Lambda site;

6. The coordinates of the locator are integrated with the brain map. The brain map version is the second version of the mouse and the sixth version of the rat. The user can select the brain map version. After selecting the version, the brain map version information is displayed;

7. Probe position and brain map display, when the user finds and sets the Bregma / Lambda point, the computer interface can display the brain map and the location of the probe, and can display the movement process in real time;

8. Automatic craniotomy program, 2 kinds of shape selection: square or round, length and width or diameter parameters (range: 0 ~ 20mm) and depth (range: 0 ~ 20mm), 5 kinds of moving speeds for AP axis and ML axis, 8 kinds of moving speed for DV axis;

9. Multi-point program setting, the user can manually input or select up to 10 coordinates on the brain map, can choose automatic operation or start the operation after the signal is triggered, the user can set whether the locator outputs TTL signal after reaching the target point, The user can set the residence time at each location (range: 00:00:00 23:59:59);

10. Tissue removal procedure, two shapes to choose: square or round, length and width or diameter parameters (range: 0 ~ 20mm) and depth (range: 0 ~ 20mm), support 2 needle specifications 27G, 30G, The density coefficient of 6 gradients is set from 1-6, and 5 kinds of moving speeds for AP axis and ML axis, 8 kinds of moving speed for DV axis;

11. Position coordinate storage function, the user can manually input or select multiple coordinates on the brain map and name, can store up to 10 points;

12. Z axis retraction function, when the user defines the Bregma / Lambda point, when the locator is moving in the X and Y directions, regardless of where the probe is located in the Z axis, the probe needs to be retracted first above the animal skull The position of 5mm on the surface ensures that the horizontal movement of the motor will not touch the skull of the animal;

13. The choice of anti-backlash function can eliminate the error caused by the gap between the motor gears when the motor moves in the reverse direction. The user can choose to turn it on or off;

14. Error log automatic saving function, convenient for product maintenance.

15. The software requires adaptation to win7, win10 Chinese and English operating systems.

16. Alarm function, real-time detection, stop all parts movement when encountering trouble, PC frame prompt;

17. Ability to receive or output TTL signals, such as receiving TTL signals to trigger the automatic brain stereotaxic instrument to automatically move according to the set procedure, or output TTL signals when reaching a specific position;

18. Micro-operation control, which can realize the continuous movement of the button of the handle to the full-automatic brain stereo locator.

19. The control box has two kinds of power indicator lights, the normal state is green light, and the abnormal state is red light;

20. The control box has 12V power interface, USB square port to communicate with the computer, 3 motor interfaces, there are silk screen logos to distinguish, BNC interface handles TTL signal.

Last Updated on January 7, 2021

Specifications

Name Cat No. Product Description Category
Automated Stereotaxic Instrument-Mice 71000-M 71000 Automated Stereotaxic Instrument host (including U disk, dongle) Standard
Control box (including power adapter, BNC data cable, 2m USB cable, grounding cable)
Micro operation (including BNC data cable)
68055 Mouse adapter
68306 Mouse 60 degree ear bar
Automated Stereotaxic Instrument-Rat 71000-R 71000 Automated Stereotaxic Instrument host (including U disk, dongle) Standard
Control box (including power adapter, BNC data cable, 2m USB cable, grounding cable)
Micro operation (including BNC data cable)
68021 Rat adapter
68301 Rat 18 degree ear bar
Automated Stereotaxic Instrument 71000 / Automated Stereotaxic Instrument host (including U disk, dongle) Standard
Control box (including power adapter, BNC data cable, 2m USB cable, grounding cable)
Micro operation (including BNC data cable)
Optional accessories / / Needle connector Optional
68202 Large Probe Holder-6.0mm-12.0mm
GM-0.5B(220V,50HZ) Vacuum pump-GM-0.5B-220V-50HZ
/ Liquid storage tank
/ Connecting pipe
/ Needle

Last Updated on January 7, 2021

Ordering

Please contact ALA Scientific sales team for ordering information.

Last Updated on January 7, 2021

Quote List

No products in the list

Related products

  • Large Animal Stereotaxic Instruments

    Show Details
  • 69100 Rotational Digital for Mice and Rats

    Show Details
  • Standard Stereotaxic Instruments

    Show Details
  • MRI Stereotaxic Instruments

    Show Details

Subscribe to our Newsletter


About Us

ALA Scientific Instruments, Inc. began as Adams and List Associates Ltd. in 1986.

Recent News

  • ALA is attending Society for NeuroScience
  • ALA is attending Biophysical Society Meeting
  • FENS FORUM 2024
  • ALA is attending Biophysical Society Meeting
  • ALA is attending Society for Neuroscience

Search Site

Copyright © 2025 - Ala Scientific Instruments, Inc.
  • Facebook
  • Twitter
  • Instagram
  • LinkedIn
  • Rss
uMs Microscope 69100 Rotational Digital for Mice and Rats
Scroll to top

This site uses cookies. By continuing to browse the site, you are agreeing to our use of cookies.

Accept settingsHide notification onlySettings

Cookie and Privacy Settings



How we use cookies

We may request cookies to be set on your device. We use cookies to let us know when you visit our websites, how you interact with us, to enrich your user experience, and to customize your relationship with our website.

Click on the different category headings to find out more. You can also change some of your preferences. Note that blocking some types of cookies may impact your experience on our websites and the services we are able to offer.

Essential Website Cookies

These cookies are strictly necessary to provide you with services available through our website and to use some of its features.

Because these cookies are strictly necessary to deliver the website, refuseing them will have impact how our site functions. You always can block or delete cookies by changing your browser settings and force blocking all cookies on this website. But this will always prompt you to accept/refuse cookies when revisiting our site.

We fully respect if you want to refuse cookies but to avoid asking you again and again kindly allow us to store a cookie for that. You are free to opt out any time or opt in for other cookies to get a better experience. If you refuse cookies we will remove all set cookies in our domain.

We provide you with a list of stored cookies on your computer in our domain so you can check what we stored. Due to security reasons we are not able to show or modify cookies from other domains. You can check these in your browser security settings.

Other external services

We also use different external services like Google Webfonts, Google Maps, and external Video providers. Since these providers may collect personal data like your IP address we allow you to block them here. Please be aware that this might heavily reduce the functionality and appearance of our site. Changes will take effect once you reload the page.

Google Webfont Settings:

Google Map Settings:

Google reCaptcha Settings:

Vimeo and Youtube video embeds:

Accept settingsHide notification only