Axon™ Digidata® 1550B Low-Noise Data Acquisition System plus HumSilencer

Digidata 1550B

Add to quote list
This product is already in quote request list
Browse the list
Category: Data Acquisition & Software Tags: amplifiers, bridge recording, electrophysiology rig, extracellular recording, in vitro recording, in vivo recording, intracellular recording, oocyte recording, patch clamp, patch clamp rig, single electrode voltage clamp, two elecrode voltage clamp, xenopus recording
  • Overview
  • Details
  • Applications
  • Specifications
  • Order
  • Download

Overview

Goodbye line-frequency noise. Hello biological signal.

Equipped with up to four HumSilencer™ channels, the Axon™ Digidata® 1550B Low Noise Data Acquisition System enables you to record multiple cells at once for cellular network studies without 50/60 Hz line-frequency noise.

The Digidata 1550B System has three different configurations. Please see the table below. For detailed specifications, please see the datasheet.

Bring a new level of simplicity to your patch-clamp electrophysiology experiments!

While offering the same digitization capabilities as its predecessors, the Axon Digidata 1550B Low Noise Data Acquisition System offers up to four HumSilencer channels. This innovative feature allows scientists to record multiple cells simultaneously for higher throughput or cellular network studies without 50/60 Hz line-frequency noise. With only a single click, eliminate the noise obscuring your biological signals of interest and simplify your workflow.

Last Updated on February 3, 2021

Details

  • Up to four channels that can eliminate 50/60 Hz line-frequency noise and associated high frequency harmonics in less than one second and with a single click
  • Digitizes a wide range of input signals from -10 to +10 V
  • Eliminates a maximum noise amplitude of up to 20 V, peak-to-peak
  • 8 analog input channels to digitize acquired signals up to 500 kHz independently
  • 8 analog output channels to send command voltage output independently
  • 8 digital out channels to control the periphery equipment used in sophisticated experiments
  • Independent analog-to-digital converters for each input channel ensure low crosstalk levels and high data acquisition rates.
  • USB 2.0 connection allows operation on virtually any current PC computer running Microsoft Windows 7 or 10 (32-bit or 64-bit) Operating System, including laptops.
  • 16-bit resolution data
  • State-of-the-art signal-to-noise ratio
  • All signal connectors on the front panel for ease of access and maintenance of the electrophysiology set-up
  • Rack-mount case for tidy installation of all components in the electrophysiology set-up
  • User guide written by scientific consultants, with the assistance of Axon Instruments staff, for straightforward start-up and as an in-depth reference.

 

Last Updated on February 3, 2021

Applications

Basic ion channel research 
Ion channels are pore proteins that are involved in a large variety of physiological processes. Basic research in the ion channel field furthers the understanding of ion channel function as well as their roles within cellular pathways and processes. Single-channel research helps with elucidating the mechanisms underlying ion channel function on a single-molecule level. Whole-cell and perforated patch clamp recordings are typically used to investigate the action of modulators on entire populations of ion channels in the membrane of a cell.
Cell pathway analysis
Ion channels are involved in many cell pathways and understanding the function of ion channels in response to changes in membrane potential or the presence or absence of other molecules is important in order to understand exactly how ion channels participate in normal and abnormal biological processes such as cell differentiation and migration, disease states, neuronal communications, etc.
Disease Research
Ion channels play a role in many diseases including hypertension, cardiac arrhythmias, gastrointestinal, immune and neuromuscular disorders, pathological pain, and cancer. By understanding the exact role that ion channels play in a particular disease, researchers might be able to find a way to affect the ion channel in such a way as to alter the course of the disease.
Safety Assessment
A critical part of drug discovery involves safety assessments, such as hERG testing, in order to eliminate any compounds with potential safety concerns. Conventional patch clamp has played an important role in collecting evidence for the absence of side effects before submission of a drug candidate to regulatory authorities. Even if automated electrophysiology has shifted safety testing to earlier stages in the drug discovery process, follow-up with conventional patch clamp is an essential step in the workflow.

Last Updated on February 3, 2021

Specifications

HumSilencer
Maximum input signal
(total of noise + signal)
±10 V
Maximum noise amplitude 20 V, peak-to-peak (on a 0 V signal)
Noise cancellation Line-frequency (50 Hz / 60 Hz) and harmonics to 10 kHz
Cancellation response time < 1 second
Analog Inputs
Number of input channels 8 single-ended
Number of ADCs 8
Sampling rates
1 Hz – 500 kHz; Maximum aggregate throughput rate is 500 kHz x 8 input channels = 4 Megasamples/s
Resolution 16-bit
Input range -10.000 V to +10.000 V
Input resistance >1 MΩ
Gain value 1
Analog Outputs
Number of channels 8
Number of DACs 8
Sampling rates 1 Hz –  500 kHz
Resolution 16-bit
Output range -10.000 V to +10.000 V
Output impedance <  0.5 Ω
Output short circuit to signal ground ±25 mA
Digital Outputs
Number of bits 8 (of 16) supported in software
SCOPE Dedicated trigger output
Output driver Advanced CMOS (AC) compatible
Output current ±4 mA source, cable
Type USB 2.0 braided
Length 3 meters
Trigger Inputs
Input type TTL compatible
TAG Rising-edge sensitive
START Rising-edge sensitive

Last Updated on February 3, 2021

Order

Digidata 1550B0 Data Acquisition System, no HumSilencer channel installed
Digidata 1550B1 Data Acquisition System plus one HumSilencer channel
Digidata 1550B4 Data Acquisition System plus four HumSilencer channels

Last Updated on February 3, 2021

Download

DigiData 1550B data sheet:

https://www.moleculardevices.com/sites/default/files/en/assets/data-sheets/dd/cns/axon-digidata-1550b-plus-humsilencer.pdf

Digidata 1550B application note:

https://www.moleculardevices.com/en/assets/app-note/dd/cns/humsilencer-smart-and-simple-feature

Last Updated on February 3, 2021

Quote List

No products in the list

Related products

  • DPA-2

    Show Details
  • Budget Friendly Dual Channel Extracellular Amplifier

    Select options This product has multiple variants. The options may be chosen on the product page
  • ION-01M

    Show Details
  • Intracellular Bridge Mode and Extracellular Amplifier

    Show Details

Subscribe to our Newsletter


About Us

ALA Scientific Instruments, Inc. began as Adams and List Associates Ltd. in 1986.

Recent News

  • ALA is attending Society for NeuroScience
  • ALA is attending Biophysical Society Meeting
  • FENS FORUM 2024
  • ALA is attending Biophysical Society Meeting
  • ALA is attending Society for Neuroscience

Search Site

Copyright © 2025 - Ala Scientific Instruments, Inc.
  • Facebook
  • Twitter
  • Instagram
  • LinkedIn
  • Rss
pCLAMP™ Software Suite ePatch
Scroll to top

This site uses cookies. By continuing to browse the site, you are agreeing to our use of cookies.

Accept settingsHide notification onlySettings

Cookie and Privacy Settings



How we use cookies

We may request cookies to be set on your device. We use cookies to let us know when you visit our websites, how you interact with us, to enrich your user experience, and to customize your relationship with our website.

Click on the different category headings to find out more. You can also change some of your preferences. Note that blocking some types of cookies may impact your experience on our websites and the services we are able to offer.

Essential Website Cookies

These cookies are strictly necessary to provide you with services available through our website and to use some of its features.

Because these cookies are strictly necessary to deliver the website, refuseing them will have impact how our site functions. You always can block or delete cookies by changing your browser settings and force blocking all cookies on this website. But this will always prompt you to accept/refuse cookies when revisiting our site.

We fully respect if you want to refuse cookies but to avoid asking you again and again kindly allow us to store a cookie for that. You are free to opt out any time or opt in for other cookies to get a better experience. If you refuse cookies we will remove all set cookies in our domain.

We provide you with a list of stored cookies on your computer in our domain so you can check what we stored. Due to security reasons we are not able to show or modify cookies from other domains. You can check these in your browser security settings.

Other external services

We also use different external services like Google Webfonts, Google Maps, and external Video providers. Since these providers may collect personal data like your IP address we allow you to block them here. Please be aware that this might heavily reduce the functionality and appearance of our site. Changes will take effect once you reload the page.

Google Webfont Settings:

Google Map Settings:

Google reCaptcha Settings:

Vimeo and Youtube video embeds:

Accept settingsHide notification only