• Facebook
  • Twitter
  • Instagram
  • LinkedIn
  • Rss
631-393-6401
  • 0Shopping Cart
ALA Scientific
  • ALA Scientific
  • Featured Product
  • Products
  • Applications
  • Company
    • Partners
    • Other Links
  • News
  • Contact
    • Contact Information
    • Ordering Information
    • Sales
    • Support
    • Distributors
  • Menu

Infrared Video Camera

IR-2000

Add to quote list
This product is already in quote request list
Browse the list
Category: Imaging and Light Sources
  • Overview
  • Features
  • Applications
  • Specifications

Overview

IR-2000 Infrared Monochrome Video Camera
Industry leading resolution, frame rates, and SIMPLICITY

The IR-2000 real-time monochrome camera is the next evolution of IR imaging for electrophysiology and other IR applications that require fast response and excellent sensitivity in both the visible and NIR (up to 1100nm).

The IR-2000 features industry leading frame rates and up to 4K Ultra HD resolution for impeccable image clarity. The user-friendly IR-Capture software provides increased flexibility and enables users to operate in auto mode or manual mode to achieve the optimal image for any IR application.

The intuitive IR-Capture software is simple to use and does not require training. Users can save images with the click of a button, access other on-screen tools such as overlays and measurements; and the digital zoom feature provides instant magnification for viewing small details in the live or captured images.

The IR-2000 is available in two models. A stand-alone configuration (camera + digital controller) with an HDMI output for direct connection to an HD (or Ultra HD) display OR a PC-ready configuration (camera head) connects to a user’s computer via USB 3.0. Please see PC performance requirements to determine if your PC is compatible.

Last Updated on March 6, 2024

Features

  • Real-time operation with adjustable frame rates and resolution
    • 3072 x 2048 @ 30fps
    • 1920 x 1080 @ 90fps
    • 640 x 480 @ 248 fps
  • Automatic/manual gain
  • Automatic/manual exposure (1/50,000 sec to 60 sec)
  • Wide Spectral Response (380nm – 1100nm)
  • Easy capture and record buttons
    • Bmp, Jpeg, Gif, Tiff, Png
  • Time lapse recording
  • Measurement tools with stored calibrations
  • On/off overlays, scale bar, annotations
  • Available as a stand-alone unit or connect to a PC
  • PC ready option compatible with Windows 8 and above (see PC requirements on spec)

Last Updated on March 6, 2024

Applications

  • Electrophysiology
  • Neurophysiology
  • Fluorescence Microscopy
  • Brightfield and Darkfield Microscopy
  • Phase Contrast
  • Semiconductor Inspection
  • Manufacturing Quality Control
  • Failure Analysis
  • Forensic Analysis
  • Teaching Environment

Last Updated on March 6, 2024

Specifications

Last Updated on March 6, 2024

Quote List

No products in the list

Related products

  • Light Stimulating Device

    Show Details
  • Optogenetics System

    Show Details
  • Dolan-Jenner Fiber Optic Illuminator

    Show Details
  • FiberOptoMeter III

    Show Details

Subscribe to our Newsletter


About Us

ALA Scientific Instruments, Inc. began as Adams and List Associates Ltd. in 1986.

Recent News

  • ALA is attending this year’s Society for Neuroscience
  • ALA is attending Society for NeuroScience
  • ALA is attending Biophysical Society Meeting
  • FENS FORUM 2024
  • ALA is attending Biophysical Society Meeting

Search Site

Copyright © 2025 - Ala Scientific Instruments, Inc.
  • Facebook
  • Twitter
  • Instagram
  • LinkedIn
  • Rss
Integration Diagram VCPlus-4 Channel Gravity Systems
Scroll to top

This site uses cookies. By continuing to browse the site, you are agreeing to our use of cookies.

Accept settingsHide notification onlySettings

Cookie and Privacy Settings



How we use cookies

We may request cookies to be set on your device. We use cookies to let us know when you visit our websites, how you interact with us, to enrich your user experience, and to customize your relationship with our website.

Click on the different category headings to find out more. You can also change some of your preferences. Note that blocking some types of cookies may impact your experience on our websites and the services we are able to offer.

Essential Website Cookies

These cookies are strictly necessary to provide you with services available through our website and to use some of its features.

Because these cookies are strictly necessary to deliver the website, refuseing them will have impact how our site functions. You always can block or delete cookies by changing your browser settings and force blocking all cookies on this website. But this will always prompt you to accept/refuse cookies when revisiting our site.

We fully respect if you want to refuse cookies but to avoid asking you again and again kindly allow us to store a cookie for that. You are free to opt out any time or opt in for other cookies to get a better experience. If you refuse cookies we will remove all set cookies in our domain.

We provide you with a list of stored cookies on your computer in our domain so you can check what we stored. Due to security reasons we are not able to show or modify cookies from other domains. You can check these in your browser security settings.

Other external services

We also use different external services like Google Webfonts, Google Maps, and external Video providers. Since these providers may collect personal data like your IP address we allow you to block them here. Please be aware that this might heavily reduce the functionality and appearance of our site. Changes will take effect once you reload the page.

Google Webfont Settings:

Google Map Settings:

Google reCaptcha Settings:

Vimeo and Youtube video embeds:

Accept settingsHide notification only