Iontophoresis Systems

MVCS Systems

Add to quote list
This product is already in quote request list
Browse the list
Category: Drug Application via Iontophoresis (MVCS systems) Tags: focal micro perfusion, perfusion outlets, perfusion system, peristaltic pump, superfusion, syringe pumps
  • Overview
  • Details
  • Models
  • Specifications
  • Downloads
  • Ordering

Overview

MVCS-Series – Iontophoresis Amplifiers

Features:

  • One or two channel versions (upgrade possible)
  • Time resolution: down to 100 µs
  • Spatial resolution: down to 1 µm
  • Simulation of synaptic events, suitable for receptor density mapping
  • Automated balancing of iontophoretic current (option)
  • Currents from tens of pA up to µA
  • High voltage, high speed current source
  • Automated electrode resistance test

Last Updated on January 27, 2022

Details

In principle, MVCS systems are available as:

  • A very fast (less than 1 ms) version with capacity compensation and electrode resistance test
  • A slower version without capacity compensation and electrode resistance test

Fast systems (MVCS-C-02C) are delivered with headstages, ground connector, a power cord and a user manual.

Slower systems (MVCS-02C) are delivered with connectors for electrode connection and ground, a power cord and a user manual (without headstages).

Standard voltage ranges are ±45 V or ±150 V. Other ranges are available on request.

NOTE: All MVCS systems are also available as one-channel versions and one-channel versions can be ugraded to two channels. Furthermore, all version can also be ordered without a balance channel.
Please contact npi electronic or your distributor for details.

Use window to the right to look for popular options and additional accessories (at additional costs). Customized configurations are possible, please contact npi electronic.

Last Updated on January 27, 2022

Models

Last Updated on January 27, 2022

Specifications

MODE of operation: 
set with two toggle switches, EJECT / RETAIN / AUTO switch enables manual or TTL
controlled operation
SET / OPERATE switch connects automatically electrode outputs to an internally grounded load, to make possible well defined presetting (SET position)
COMPENSATE / OFF / EXTERN switch (balance unit), selects compensation signal or connects
balance module to external signal source (additional channel).

HEADSTAGES: 
Size (approx.): Standard 70x30x25 mm, holding bar diameter 8 mm, length 150 mm (±15 V, ±45 V), optional: 100x50x20 mm (± 150V) or 225x40x60mm (± 225V).
Electrode connector: BNC connector, (headstage with driven shield also available).
Ground connector: 2.4 mm connector.
Electrode output: floating current source, output impedance >1012 Ω

ELECTRODE RESISTANCE TEST: 

1 mV / MΩ at the voltage monitor Vel / 10, obtained by application of square current pulses,
±10 nA from built-in pulse generator.

EJECT: 
ten-turn control, switch selected range max. 1 µA / 100 nA.

RETAIN: 
ten-turn control, max. 100 nA.

CAPACITY COMPENSATION: 
range 0 ­ 30 pF, ten-turn control.

MAXIMUM CURRENT: 

150 nA (±15 V), 450 nA (±45 V standard voltage), 1.5 µA (±150 V) into 100 MΩ load. Other ranges available on request.
OUTPUT CURRENT POLARITY:
selected by INVERTED / NORMAL toggle switch.
BALANCE OUTPUT (MVCS-X-02C-45, MVCC):
inverted sum of all currents, sensitivity 1 µA / V, for connecting external balance module.

TTL INPUT (AUTO mode):
LO = RETAIN, HI = EJECT, isolated, Rin > 5 kΩ
ANALOG INPUT: 
sensitivity 100 nA / V, Rin > 100 kΩ, range ±10 V.

CURRENT MONITOR: 
sensitivity 100 nA / V, Rout = 250 Ω, not isolated.

VOLTAGE MONITOR: 

Vel / 10, Rout = 250 Ω, not isolated.

DISPLAY: 

current XXXX nA, balance current XX.XX µA, voltage XXX.X V, REL XXXX MΩ,
separate displays for each channel, displayed value is set by a three position toggle switch.
OVER LEDs:
activated 10 % below maximum current.

POWER REQUIREMENTS: 
115 / 230 V AC, 45 – 60 W.

DIMENSIONS: 
19″ cabinet, 19“ (483 mm), x 10″ (250 mm) x 3.5″ (88 mm).

Last Updated on January 27, 2022

Downloads

Manual:
MVCS Manual

Brochure:
MVCS Brochure

References:
MVCS Reference List

Last Updated on January 27, 2022

Ordering

Part No. Description
MVCS-01-45* MVCS-01-45V 19″ Iontophoresis System
MVCS-01C-45* MVCS-01C-45V 19″ Iontophoresis System (with balance)
MVCS-02-45* MVCS-02-45V 19″ Iontophoresis System
MVCS-02C-45* MVCS-02C-45V 19″ Iontophoresis System (with balance)
MVCS-C-01-45* MVCS-C-01-45V 19″ Iontophoresis System
MVCS-C-01C-45* MVCS-C-01C-45V 19″ Iontophoresis System (with balance)
MVCS-C-02-45* MVCS-C-02-45V 19″ Iontophoresis System
MVCS-C-02C-45* MVCS-C-02C-45V 19″ Iontophoresis System (with balance)
MVCS-01M-45* MVCS-01M-45V Module for EPMS-H
MVCS-02M-45* MVCS-02M-45V Module for EPMS-H
MVCC-M-45* Balance Module f. MVCS-45 System for EPMS-H
MVCS-C-01M-45* MVCS-C-01M-45V Module for EPMS-H
MVCS-C-02M-45* MVCS-C-02M-45V Module for EPMS-H
MVCC-C-M-45* Balance Module f. MVCS-C-45 System for EPMS-H
MVCS-HS-45* Headstage for MVCS-45 Systems
MVCC-MOD Passive cell model for MVCS Systems

Last Updated on January 27, 2022

Quote List

No products in the list

Related products

  • Programmable Single-Syringe Microfluidics Pump

    Show Details
  • Reservoirs

    Select options This product has multiple variants. The options may be chosen on the product page
  • Modular Pressure Ejection Systems

    Show Details
  • QMM MicroManifold® Series

    Show Details

Subscribe to our Newsletter


About Us

ALA Scientific Instruments, Inc. began as Adams and List Associates Ltd. in 1986.

Recent News

  • ALA is attending this year’s Society for Neuroscience
  • ALA is attending Society for NeuroScience
  • ALA is attending Biophysical Society Meeting
  • FENS FORUM 2024
  • ALA is attending Biophysical Society Meeting

Search Site

Copyright © 2025 - Ala Scientific Instruments, Inc.
  • Facebook
  • Twitter
  • Instagram
  • LinkedIn
  • Rss
Modular Pressure Ejection Systems Modular Iontophoresis System
Scroll to top

This site uses cookies. By continuing to browse the site, you are agreeing to our use of cookies.

Accept settingsHide notification onlySettings

Cookie and Privacy Settings



How we use cookies

We may request cookies to be set on your device. We use cookies to let us know when you visit our websites, how you interact with us, to enrich your user experience, and to customize your relationship with our website.

Click on the different category headings to find out more. You can also change some of your preferences. Note that blocking some types of cookies may impact your experience on our websites and the services we are able to offer.

Essential Website Cookies

These cookies are strictly necessary to provide you with services available through our website and to use some of its features.

Because these cookies are strictly necessary to deliver the website, refuseing them will have impact how our site functions. You always can block or delete cookies by changing your browser settings and force blocking all cookies on this website. But this will always prompt you to accept/refuse cookies when revisiting our site.

We fully respect if you want to refuse cookies but to avoid asking you again and again kindly allow us to store a cookie for that. You are free to opt out any time or opt in for other cookies to get a better experience. If you refuse cookies we will remove all set cookies in our domain.

We provide you with a list of stored cookies on your computer in our domain so you can check what we stored. Due to security reasons we are not able to show or modify cookies from other domains. You can check these in your browser security settings.

Other external services

We also use different external services like Google Webfonts, Google Maps, and external Video providers. Since these providers may collect personal data like your IP address we allow you to block them here. Please be aware that this might heavily reduce the functionality and appearance of our site. Changes will take effect once you reload the page.

Google Webfont Settings:

Google Map Settings:

Google reCaptcha Settings:

Vimeo and Youtube video embeds:

Accept settingsHide notification only