Overview
MVCS Series – Iontophoresis Amplifiers
Features:
- Time resolution: down to 100 µs, spatial resolution: down to 1 µm
- Simulation of synaptic events, suitable for receptor density mapping
- Automated balancing of iontophoretic current (option)
- Currents from tens of pA up to µA
- High-voltage, high-speed current source
- Automated electrode resistance test
Works only with EPMS-H-07!
Last Updated on January 31, 2022
Specifications
HEADSTAGES:
Size (approx.): Standard 65x25x25 mm, holding bar diameter 8 mm, length 150 mm, mounting plate or dovetail on request,
Electrode connector: BNC connector,
Ground connector: 2.4 mm connector.
Electrode output: floating current source, output impedance >1012 Ω.
MAXIMUM CURRENT:
±450 nA (±45 V) or ±1.5 µA (±150 V) into 100 MΩ load. Other ranges available on request.
DISPLAY:
current XXXX nA, voltage XXX.X V, REL XXXX MΩ,
separate displays for each channel, displayed value is set by a three position toggle switch.
OVER LEDs:
activated 10 % below maximum current.
EJECT:
ten-turn control, switch selected range max. 1 µA / 100 nA.
RETAIN:
ten-turn control, max. 100 nA.
CAPACITY COMPENSATION:
range 0 30 pF, ten-turn control.
OUTPUT CURRENT POLARITY:
selected by INVERTED / NORMAL toggle switch.
MODE of operation:
set with toggle switches,
EJECT / RETAIN / AUTO switch enables manual or TTL controlled operation,
SET / OPERATE switch connects automatically electrode outputs to an internally grounded load, to make possible well defined presetting (SET position),
TTL INPUT (AUTO mode):
LO = RETAIN, HI = EJECT, isolated, Rin > 5 kΩ.
ANALOG INPUT:
sensitivity 100 nA / V, Rin > 100 kΩ, range ±10 V.
CURRENT MONITOR:
sensitivity 100 nA / V, Rout = 50 Ω, not isolated.
VOLTAGE MONITOR:
Vel / 10, Rout = 50 Ω, not isolated.
ELECTRODE RESISTANCE TEST:
obtained by application of square current pulses, ±10 nA from built-in pulse generator.
POWER REQUIREMENTS:
115 / 230 V AC, 45 – 60 W.
Last Updated on January 31, 2022
Downloads
Manual:
MVCS/MVCC Manual
Brochure:
MVCS Brochure
References:
MVCS Reference List
Last Updated on January 31, 2022
Ordering
Part No. |
Description |
MVCS-01-45* |
MVCS-01-45V 19″ Iontophoresis System |
MVCS-01C-45* |
MVCS-01C-45V 19″ Iontophoresis System (with balance) |
MVCS-02-45* |
MVCS-02-45V 19″ Iontophoresis System |
MVCS-02C-45* |
MVCS-02C-45V 19″ Iontophoresis System (with balance) |
|
|
MVCS-C-01-45* |
MVCS-C-01-45V 19″ Iontophoresis System |
MVCS-C-01C-45* |
MVCS-C-01C-45V 19″ Iontophoresis System (with balance) |
MVCS-C-02-45* |
MVCS-C-02-45V 19″ Iontophoresis System |
MVCS-C-02C-45* |
MVCS-C-02C-45V 19″ Iontophoresis System (with balance) |
|
|
MVCS-01M-45* |
MVCS-01M-45V Module for EPMS-H |
|
|
MVCS-02M-45* |
MVCS-02M-45V Module for EPMS-H |
|
|
MVCC-M-45* |
Balance Module f. MVCS-45 System for EPMS-H |
|
|
MVCS-C-01M-45* |
MVCS-C-01M-45V Module for EPMS-H |
|
|
MVCS-C-02M-45* |
MVCS-C-02M-45V Module for EPMS-H |
|
|
MVCC-C-M-45* |
Balance Module f. MVCS-C-45 System for EPMS-H |
|
|
MVCS-HS-45* |
Headstage for MVCS-45 Systems |
MVCC-MOD |
Passive cell model for MVCS Systems |
Requires EPMS-H-07 high voltage power supply rack