• Facebook
  • Twitter
  • Instagram
  • LinkedIn
  • Rss
631-393-6401
  • 0Shopping Cart
ALA Scientific
  • ALA Scientific
  • Featured Product
  • Products
  • Applications
  • Company
    • Partners
    • Other Links
  • News
  • Contact
    • Contact Information
    • Ordering Information
    • Sales
    • Support
    • Distributors
  • Menu

Motorized and Manual Translation Systems for fixed-stage microscopes

X-Y Translation System for Fixed-Stage Microscopes

Add to quote list
This product is already in quote request list
Browse the list
Category: Stages Tags: adapters, hydraullic micromanipulator, magnetic stands, manual micromanipulator, mechanical micromanipulator, micromanipulation, micromanipulator, microscope mounting, microscope stages, microscope translators, motorized micromanipulator, Narishige, Sutter
  • Overview
  • Specifications
  • Ordering

Overview

The MT-1000/MT-1078 is a microscope translator, fixed-stage and manipulator platform for moving optical pathway electrophysiology. Two general styles are available. In the classic design (MT-1000), an independent stand is used for each manipulator and a similar stand holds the tissue chamber. A new style (MT-1078) uses a single large, fixed stage that is used for multiple manipulators and for the sample as well.

MT-1000: the classic modular design features free-standing columns that provide rock solid mounting for the tissue recording chamber (MT-150) and multiple micromanipulators (MT-75). The columns are positioned around a movable table that provides X-Y translation of the optical pathway in order to view multiple locations within the chamber at high resolution. Many prefer this methodology as it maximizes working room for adjusting the microscope and changing pipettes. Furthermore, the independent stand design minimizes movement-related cross talk between manipulators.

In the new MT-1078 translator system, the large fixed stage MT-78-FS is employed. In this design, it is easy to add additional manipulators and other devices to expand a setup as the manipulator/chamber support is a single large platform. Furthermore, an available magnetic stainless steel insert holds the chamber and allows the easy positioning of magnetically attached small devices nearby

At the core of both the MT-1000 and MT-1078 translator systems is the MT-500 X-Y translation table. It is designed to allow movement of a microscope’s optics with respect to the fixed stage(s). This methodology was developed by electrophysiologists recording from tissue slice preparations. The translator allows visualization and/or imaging of multiple tissue locations while maintaining multiple stable recordings from the preparation. Such a system is also useful for experiments on cells in culture where one wishes to monitor several cells not in the same field of view, e.g. recording from pre and post synaptic neurons in culture and/or imaging one cell while recording from or stimulating another.

Translators are available for the Olympus BX-51WI, Nikon FN-1, Zeiss Axioskop 2 FS and the Leica DMLFS as well as older fixed stage models.. Inverted microscope translators are available for the Olympus IX71.

Various different recording chambers can be accommodated in either the MT-150 chamber column or the insert in the MT-78-FS large stage. Sutter currently supports the Warner Instruments/Harvard Apparatus Series 20 chambers and the ALA 35mm chambers. Others can be accommodated. Dovetail slides for the MT-150 or inserts for the MT-78-FS are available with generic openings for users who wish to develop custom chambers.

FEATURES

  • 25mm travel in X & Y
  • 5 micron resolution
  • Open design allows easy access to specimen and microscope
  • Highly stable for experiments intolerant of drift
  • Accomodates a variety of stage inserts
  • Compatible with Nikon, Olympus, Zeiss and Leica upright and inverted microscopes

Last Updated on May 13, 2021

Specifications

Baseplate Dimensions
8 in x 15.25 in x 2.25 in | 200 mm x 375 mm x 55 mm

Maximum Travel
1 in | 25 mm

Resolution
0.0002 in | 5µm

Maximum Load
100 lbs | 50 kg

Weight
35 lbs | 16 kg

RoHS Compliant

Last Updated on May 13, 2021

Ordering

COMPLETE SYSTEM w/ MT-75 MANIPULATOR STANDS
Includes the MT-500 manual X-Y translator, MT-150 chamber column, two MT-75 micromanipulator columns (without linear slide)

Catalog Number Description
MT-1000/Y511 Complete system for the Olympus BX51WI
MT-1000/Y711 Complete system for the Olympus IX71
MT-1000/Z251 Complete system for the Zeiss Axioskop 2 FS
MT-1000/Z451 Complete system for the Zeiss Axio Examiner
MT-1000/N651 Complete system for the Nikon FN1
MT-1000/L301 Complete system for the Leica DMLFS
MT-1000/L351 Complete system for the Leica DM6000 FS

COMPLETE SYSTEM w/ MT-78 FIXED STAGE PLATFORM
Includes the MT-500 manual X-Y translator and MT-78-FS fixed stage platform

Catalog Number Description
MT-1078/Y511 Complete system for the Olympus BX51WI
MT-1078/Y711 Complete system for the Olympus IX71
MT-1078/Z251 Complete system for the Zeiss Axioskop 2 FS
MT-1078/Z451 Complete system for the Zeiss Axio Examiner
MT-1078/N651 Complete system for the Nikon FN1
MT-1078/L301 Complete system for the Leica DMLFS
MT-1078/L351 Complete system for the Leica DM6000 FS

1 Please specify chamber type when ordering


CHAMBER INSERTS
Stage Inserts At-A-Glance

Catalog Number Description
X0405002 Warner Series 20 (round) – aluminum
X0405032 Warner Series 20 (round) – stainless steel
X0405052 Warner Series 20 (octagonal) – aluminum
X0405072 Warner Series 20 (octagonal) – stainless steel
X0405102 50mm round – aluminum
X0405122 50mm round – stainless steel
X0404972 Blank insert – aluminum
X0404982 Blank insert – stainless steel
SI-SLIDE2 Insert with slide holder
SI-PETRI For petri dish and slides
SI-W302 Warner Series 30 platform – aluminum
SI-W30ST2 Warner Series 30 platform – stainless steel

2 no charge when ordered with MT-1000 or MT-1078


TRANSLATORS

Catalog Number Description
MT-500/Y50 X-Y translator for Olympus BX50WI
MT-500/Y51 X-Y translator for Olympus BX51WI
MT-500/Y71 X-Y translator for Olympus IX71
MT-500/N65 X-Y translator for Nikon FN1
MT-500/L30 X-Y translator for Leica DMLFS
MT-500/L35 X-Y translator for Leica DM6000 FS
MT-500/Z20 X-Y translator for Zeiss Axioskop FS
MT-500/Z25 X-Y translator for Zeiss Axioskop 2 FS
MT-500/Z45 X-Y translator for Zeiss Axio Examiner

CHAMBER COLUMNS

Catalog Number Description
MT-150/W20 Chamber column for Warner Series 20 chamber (octagon)
MT-150/W20R Chamber column for Warner Series 20 chamber (round)
MT-150/ALA35 Chamber column for ALA 35mm chamber
MT-150/CUST Chamber column for non-standard recording chamber
MT-150/PT Chamber column for petrie dish or lid
MT-150/AUTO Chamber column for Automate round stage adapter

MANIPULATOR COLUMNS

Catalog Number Description
MT-75 Standard gantry stand 8.7 to 13.4 in (22.1 to 33.9 cm)
MT-75S3 Short gantry stand 6.7 to 9.6 in (16.9 to 24.4 cm)
MT-75T Tall gantry stand 10.7 to 15.4 in (27.1 to 39.1 cm)
MT-75XT Extra tall gantry stand 14.71 to 18.50 in (37.4 to 47 cm)
MT-75/LS3 Standard gantry stand with linear slide
MT-75S/LS3 Short gantry stand with linear slide
MT-75T/LS Tall gantry stand with linear slide
MT-75XT/LS3 Extra tall gantry stand with linear slide

3 Useful for most upright scopes and the Axiovert 25 inverted scope with low stage plate


PLATFORM STAGE

Catalog Number Description
MT-78-FS3 Fixed platform stage and gantry support
MT-78-FS/M63 Same as MT-78-FS except with M6 tapped holes

3 Useful for most upright scopes and the Axiovert 25 inverted scope with low stage plate

Last Updated on May 13, 2021

Quote List

No products in the list

Related products

  • WR-6

    Show Details
  • NR-12

    Show Details
  • MHW-3

    Show Details
  • NMN-25

    Show Details

Subscribe to our Newsletter


About Us

ALA Scientific Instruments, Inc. began as Adams and List Associates Ltd. in 1986.

Recent News

  • ALA is attending Society for NeuroScience
  • ALA is attending Biophysical Society Meeting
  • FENS FORUM 2024
  • ALA is attending Biophysical Society Meeting
  • ALA is attending Society for Neuroscience

Search Site

Copyright © 2025 - Ala Scientific Instruments, Inc.
  • Facebook
  • Twitter
  • Instagram
  • LinkedIn
  • Rss
MD Series Micromanipulator Stands
Scroll to top

This site uses cookies. By continuing to browse the site, you are agreeing to our use of cookies.

Accept settingsHide notification onlySettings

Cookie and Privacy Settings



How we use cookies

We may request cookies to be set on your device. We use cookies to let us know when you visit our websites, how you interact with us, to enrich your user experience, and to customize your relationship with our website.

Click on the different category headings to find out more. You can also change some of your preferences. Note that blocking some types of cookies may impact your experience on our websites and the services we are able to offer.

Essential Website Cookies

These cookies are strictly necessary to provide you with services available through our website and to use some of its features.

Because these cookies are strictly necessary to deliver the website, refuseing them will have impact how our site functions. You always can block or delete cookies by changing your browser settings and force blocking all cookies on this website. But this will always prompt you to accept/refuse cookies when revisiting our site.

We fully respect if you want to refuse cookies but to avoid asking you again and again kindly allow us to store a cookie for that. You are free to opt out any time or opt in for other cookies to get a better experience. If you refuse cookies we will remove all set cookies in our domain.

We provide you with a list of stored cookies on your computer in our domain so you can check what we stored. Due to security reasons we are not able to show or modify cookies from other domains. You can check these in your browser security settings.

Other external services

We also use different external services like Google Webfonts, Google Maps, and external Video providers. Since these providers may collect personal data like your IP address we allow you to block them here. Please be aware that this might heavily reduce the functionality and appearance of our site. Changes will take effect once you reload the page.

Google Webfont Settings:

Google Map Settings:

Google reCaptcha Settings:

Vimeo and Youtube video embeds:

Accept settingsHide notification only