Laser-Based Micropipette Puller

Clear
Add to quote list
This product is already in quote request list
Browse the list
SKU: N/A Category: Electrode Pullers Tags: beveler, electrode puller, microforge, micropipette polisher, patch pipette glass, patch pipette polishing, patch pipette puller, pipette puller
  • Description
  • Specifications
  • Downloads
  • Ordering

Description

The P-2000 micropipette puller represents a significant advance in the technology of fabrication of micropipettes, optical fiber probes, and nanospray tips. The P-2000 integrates a CO2 laser-based heat source with the technology derived from our extensive experience with conventional pullers. This system offers capabilities unmatched by other pullers.

While the P-2000 is suitable for working with most conventional glasses, its primary advantage is the ability to work with quartz glass (fused silica). Quartz offers superior material properties for a variety of research applications. Quartz is stronger than other glasses and can facilitate penetration through tough tissues which would normally break conventional pipettes1 . For applications requiring a low noise glass, users will find that quartz is the lowest noise glass available2,4. Quartz contains none of the metals used in conventional glasses3. Optically, quartz is virtually free from fluorescence when illuminated.

A CO2 laser was selected as the heat source for the P-2000 for several reasons. First, the nominal emission wavelength of the laser approximates the resonant frequency of the SiO2 lattice in glass. Thus, quartz and other conventional glasses can be melted when the appropriate laser power is supplied. Second, laser heat is clean and leaves no metal residue on the pipette as do conventional heating filaments. Third, laser heat can be turned off instantly, leaving no residual filament heat. Lastly, the user can program the amount and distribution of heat supplied to the glass.

The P-2000 can store up to 100 separate programs, with each program consisting of up to 8 command lines. Programmable parameters include; laser power level, scan width, trip velocity, delay/ laser on time, and hard pull strength.

One important consideration for the use of the P-2000 is the diameter of the glass used. The P-2000/G is designed to produce even heating on glass up to 1.2 mm in outside diameter. Larger diameter glasses can be used with the P-2000/G (up to 1.5 mm quartz and 1.8 mm conventional glasses), but the performance is best with glass that is 1.2 mm diameter or less.

The P-2000/F works well with small diameter glasses such as optical fibers, and with small diameter fused silica capillary commonly used for the manufacture of nanospray tips. Small diameter glass (outer diameter in the range of 0.125 mm to 0.6 mm) requires special puller bars as well as an optical alignment optimized for the smaller diameter material.

As with larger diameter glass, a wide range of tip sizes and taper geometries can be produced with the P-2000/F and small diameter glass. We have drawn optical fiber tips ranging from less than 10nm to more than 5µm. Please consult our technical staff for further information.

FEATURES

  • Capable of pulling quartz, borosilicate and aluminosilicate glass.
  • Fully programmable – including heating filament characteristics.
  • The laser has no melting point limit as with conventional metal filaments; and therefore, cannot be burned out.
  • Pulls electrodes with tip diameters smaller than 0.03µm.
  • Optimized velocity sensing circuit for maximized sensitivity and reproducibility.*
  • Operating life of the CO2 laser is expected to be in excess of ten years with normal use, after which the laser can be refurbished by the Sutter Instrument Company for a nominal charge.
  • Individual programs can be write-protected in order to secure them from inadvertent changes.
  • The total time that the heat is on during the pull is displayed for improved program development and troubleshooting.
  • A date and time stamp is displayed to show the last time that a program has been changed.
  • The P-2000/F is ideal for applications such as nanospray and NSOM.
  • Preprogrammed sample programs for intra-cellular and patch pipettes. The P-2000/F also comes with an NSOM tip program.

REFERENCES
These references describe the Flaming/Brown pullers and contain valuable information applicable to the P-2000.

  • 1 Munoz, J.L. and Coles, J. Quartz micropipettes for intracellular voltage micro- electrodes and ion selective microelectrodes. Journal of Neuroscience Methods: 22:57-64, 1987.
  • 2 Rae, J.L. and Levis, R. A. A method for exceptionally low noise single channel recordings. European Journal of Physiology – Pflügers Archiv: 420:618-620, 1992.
  • 3 Zuazaga, C. and Steinacker, A. Patch-clamp recording of ion channels: Interfering effects of patch pipette glass. News in Physiological Science: 5:155-159, 1990.
  • 4 Levis, R.A. and Rae, J. L. The use of quartz patch pipettes for low noise single channel recording. Biophysical Journal: 65:1666-1677, 1993.

Last Updated on April 28, 2021

Specifications

Dimensions
30in x 14.25in x 13.25in
76cm x 36cm x 33.5cm

Weight
90 lbs | 41 kg

Electrical
115/230 volts
50/60 Hertz power line

*Patent No.4,600,424

CLASS 1 LASER PRODUCT

CE Certificate

Last Updated on April 28, 2021

Downloads

USER MANUALS
P-2000 Operation Manual

PRODUCT INFORMATION
TECHNOTES: Which P-2000 model do I need?
TECHNOTES: Novel applications for P-2000
How to Prepare your P-2000 for Shipping or Relocation
Sutter Instrument Puller Comparison Chart
P-2000 Sales Flyer

VIDEO TUTORIALS:
P-2000 Introduction
Pulling a Patch Pipette From Quartz Glass
Effects of The Velocity Parameter
Copying Pull Programs on the P-2000 Puller
Troubleshooting Pipette Variablity
Puller Bars and V-groove Bearings
Checking the Pull Cables
Checking the Cable Pulleys

Last Updated on April 28, 2021

Ordering

Catalog Number Description
P-2000/G Laser-based puller, for use with glass GREATER than 0.6mm OD
P-2000/F Laser-based puller, for use with glass LESS than 0.6mm OD

ACCESSORIES

Catalog Number Description
FPS Spacer for special procedures
GS1 Glass stop
GLA1 Glass loading aid
CTS Ceramic tile for scoring glass
PET Pipette examining tile
BX102 Pipette storage box – Holds 10 (4 3/4 x 3 5/8 x 3/4 inches)
BX202 Pipette storage box – Holds 20 (7 x 3 5/8 x 3/4 inches)
O730350 Mirrored tile

1 Installs on either puller bar
2 Minimum order of any 2 boxes

Last Updated on April 28, 2021

Quote List

No products in the list

Related products

  • EG-45

    Show Details
  • Capillary Glass & Filaments

    Select options This product has multiple variants. The options may be chosen on the product page
  • P-30

    Select options This product has multiple variants. The options may be chosen on the product page
  • P-97

    Show Details

Subscribe to our Newsletter


About Us

ALA Scientific Instruments, Inc. began as Adams and List Associates Ltd. in 1986.

Recent News

  • ALA is attending this year’s Society for Neuroscience
  • ALA is attending Society for NeuroScience
  • ALA is attending Biophysical Society Meeting
  • FENS FORUM 2024
  • ALA is attending Biophysical Society Meeting

Search Site

Copyright © 2025 - Ala Scientific Instruments, Inc.
  • Facebook
  • Twitter
  • Instagram
  • LinkedIn
  • Rss
P-1000 PC-100
Scroll to top

This site uses cookies. By continuing to browse the site, you are agreeing to our use of cookies.

Accept settingsHide notification onlySettings

Cookie and Privacy Settings



How we use cookies

We may request cookies to be set on your device. We use cookies to let us know when you visit our websites, how you interact with us, to enrich your user experience, and to customize your relationship with our website.

Click on the different category headings to find out more. You can also change some of your preferences. Note that blocking some types of cookies may impact your experience on our websites and the services we are able to offer.

Essential Website Cookies

These cookies are strictly necessary to provide you with services available through our website and to use some of its features.

Because these cookies are strictly necessary to deliver the website, refuseing them will have impact how our site functions. You always can block or delete cookies by changing your browser settings and force blocking all cookies on this website. But this will always prompt you to accept/refuse cookies when revisiting our site.

We fully respect if you want to refuse cookies but to avoid asking you again and again kindly allow us to store a cookie for that. You are free to opt out any time or opt in for other cookies to get a better experience. If you refuse cookies we will remove all set cookies in our domain.

We provide you with a list of stored cookies on your computer in our domain so you can check what we stored. Due to security reasons we are not able to show or modify cookies from other domains. You can check these in your browser security settings.

Other external services

We also use different external services like Google Webfonts, Google Maps, and external Video providers. Since these providers may collect personal data like your IP address we allow you to block them here. Please be aware that this might heavily reduce the functionality and appearance of our site. Changes will take effect once you reload the page.

Google Webfont Settings:

Google Map Settings:

Google reCaptcha Settings:

Vimeo and Youtube video embeds:

Accept settingsHide notification only