pCLAMP™ Software Suite

Patch Clamp – Software

Add to quote list
This product is already in quote request list
Browse the list
Category: Data Acquisition & Software Tags: amplifiers, bridge recording, electrophysiology rig, extracellular recording, in vitro recording, in vivo recording, intracellular recording, oocyte recording, patch clamp, patch clamp rig, single electrode voltage clamp, two elecrode voltage clamp, xenopus recording
  • Overview
  • Specifications
  • Applications
  • Download

Overview

The Axon™ pCLAMP™ Software Suite is the most widely-used patch-clamp electrophysiology data acquisition and analysis program for control and recording of voltage-clamp, current-clamp, and patch-clamp experiments.

The software suite consists of:

  • Axon Clampex 11 Software for data acquisition
  • Axon AxoScope 11 Software for background recording
  • Axon Clampfit 11 Software for data analysis
  • Clampfit Advanced Analysis module (optional) for sophisticated and streamlined analysis

Last Updated on February 3, 2021

Specifications

Minimum System Requirements Recommended System Requirements
Operating system Windows 7 Pro (32-bit)** Windows 10 Pro (32- or 64-bit)**
CPU PC with 2 GHz processor PC with 2.0 GHz (or faster) Duo Processor
RAM 1.2 GB RAM 4 GB or higher
Display 1440 x 900 display 1920 x 1080 display or higher
Ports 1 USB 1 port (for security key dongle)
1 USB 2.0 port (for Digidata digitizers)
3 USB 2.0 ports
Supported hardware • Digidata 1550B 8-Channel Digitizer
• Digidata 1440A 16-Channel Digitizer
• MiniDigi 1B Two-Channel Digitizer
• Axoclamp 900A Microelectrode Amplifier
• Axopatch 200B Microelectrode Amplifier
• MultiClamp 700B Microelectrode Amplifier
• Most BNC-telegraphed amplifiers also supported*
• Digidata 1550B 8-Channel Digitizer
• Digidata 1440A 16-Channel Digitizer
• MiniDigi 1B Two-Channel Digitizer
• Axoclamp 900A Microelectrode Amplifier
• Axopatch 200B Microelectrode Amplifier
• MultiClamp 700B Microelectrode Amplifier
• Most BNC-telegraphed amplifiers also supported*

Last Updated on February 3, 2021

Applications

Basic ion channel research 
Ion channels are pore proteins that are involved in a large variety of physiological processes. Basic research in the ion channel field furthers the understanding of ion channel function as well as their roles within cellular pathways and processes. Single-channel research helps with elucidating the mechanisms underlying ion channel function on a single-molecule level. Whole-cell and perforated patch clamp recordings are typically used to investigate the action of modulators on entire populations of ion channels in the membrane of a cell. Learn more.
Cell pathway analysis
Ion channels are involved in many cell pathways and understanding the function of ion channels in response to changes in membrane potential or the presence or absence of other molecules is important in order to understand exactly how ion channels participate in normal and abnormal biological processes such as cell differentiation and migration, disease states, neuronal communications, etc.
Disease Research
Ion channels play a role in many diseases including hypertension, cardiac arrhythmias, gastrointestinal, immune and neuromuscular disorders, pathological pain, and cancer. By understanding the exact role that ion channels play in a particular disease, researchers might be able to find a way to affect the ion channel in such a way as to alter the course of the disease.

Safety Assessment
A critical part of drug discovery involves safety assessments, such as hERG testing, in order to eliminate any compounds with potential safety concerns. Conventional patch clamp has played an important role in collecting evidence for the absence of side effects before submission of a drug candidate to regulatory authorities. Even if automated electrophysiology has shifted safety testing to earlier stages in the drug discovery process, follow-up with conventional patch clamp is an essential step in the workflow.

Last Updated on February 3, 2021

Download

The Axon™ pCLAMP™ Software Suite data sheet:

https://www.moleculardevices.com/sites/default/files/en/assets/data-sheets/dd/cns/axon-pclamp-11-software-suite.pdf

Last Updated on February 3, 2021

Quote List

No products in the list

Related products

  • Extracellular Electrophysiology Data Acquisition

    Show Details
  • PA-01GX

    Show Details
  • TEC-10CX for High-Speed Oocyte Recording

    Show Details
  • Budget Friendly Dual Channel Extracellular Amplifier

    Select options This product has multiple variants. The options may be chosen on the product page

Subscribe to our Newsletter


About Us

ALA Scientific Instruments, Inc. began as Adams and List Associates Ltd. in 1986.

Recent News

  • ALA is attending Society for NeuroScience
  • ALA is attending Biophysical Society Meeting
  • FENS FORUM 2024
  • ALA is attending Biophysical Society Meeting
  • ALA is attending Society for Neuroscience

Search Site

Copyright © 2025 - Ala Scientific Instruments, Inc.
  • Facebook
  • Twitter
  • Instagram
  • LinkedIn
  • Rss
USB Multifunction 2 channel Arbitrary Waveform Generator Axon™ Digidata® 1550B Low-Noise Data Acquisition System plus HumSilencer
Scroll to top

This site uses cookies. By continuing to browse the site, you are agreeing to our use of cookies.

Accept settingsHide notification onlySettings

Cookie and Privacy Settings



How we use cookies

We may request cookies to be set on your device. We use cookies to let us know when you visit our websites, how you interact with us, to enrich your user experience, and to customize your relationship with our website.

Click on the different category headings to find out more. You can also change some of your preferences. Note that blocking some types of cookies may impact your experience on our websites and the services we are able to offer.

Essential Website Cookies

These cookies are strictly necessary to provide you with services available through our website and to use some of its features.

Because these cookies are strictly necessary to deliver the website, refuseing them will have impact how our site functions. You always can block or delete cookies by changing your browser settings and force blocking all cookies on this website. But this will always prompt you to accept/refuse cookies when revisiting our site.

We fully respect if you want to refuse cookies but to avoid asking you again and again kindly allow us to store a cookie for that. You are free to opt out any time or opt in for other cookies to get a better experience. If you refuse cookies we will remove all set cookies in our domain.

We provide you with a list of stored cookies on your computer in our domain so you can check what we stored. Due to security reasons we are not able to show or modify cookies from other domains. You can check these in your browser security settings.

Other external services

We also use different external services like Google Webfonts, Google Maps, and external Video providers. Since these providers may collect personal data like your IP address we allow you to block them here. Please be aware that this might heavily reduce the functionality and appearance of our site. Changes will take effect once you reload the page.

Google Webfont Settings:

Google Map Settings:

Google reCaptcha Settings:

Vimeo and Youtube video embeds:

Accept settingsHide notification only