Overview
Combine the DigiStim Stimulator and the ELectroPORATOR to form a flexible single cell electroporation system
Single-cell Electroporation is a flexible method to transfect individual cells in cell culture or tissue.
- Transfect individual cells for GFP expression
- Target single cells for optogenetics, etc.
- Deliver macromolecules, including DNA, RNA, dyes and proteins
into cells
- Stain cells to study their morphology
Last Updated on February 3, 2021
Details
The ELectroPORATOR is an amplifier providing voltage pulses of up to 100V and current pulses up to 10mA which are timed and shaped by an external function generator or data acquisition system. It features offset and capacity compensation and a classical headstage. An audio monitor for electrode resistance, current or voltage is useful for approaching cells and completes the functionality of this instrument.
The combination with ALA’s DigiStim Waveform Generator forms a fully independent single cell electroporation system.
- Voltage up to 100V, current up to 10mA
- 3 current and 3 voltage ranges
- Audio monitor for resistance, voltage or current
- Offset compensation for voltage operation
- Offset and capacity compensation for current operation
- Footswitch, pushbutton or TTL trigger for DigiStim or data acquisition system
- Classical headstage for electrode fixation
With DiGiStim
- Program any arbitrary waveform e.g.square, sine, ramps, any combination
- Program, store and recall your pulse protocol with DigiStim
- Recall protocol stored on the DigiStim independent of a PC
Last Updated on February 3, 2021
Specifications
Output modes:
voltage source, current source
selectable with rotary switch
Scaling:
Voltage output: x 0.2 V/V
x 2 V/V
x 20 V/V
Current output:
x 2 mA/V
x 200 µA/V
x 20 µA/V
Displays:
Potential:
XXX.X V
Current:
XXX.X µA in x20 µA/V scaling
XXXX µA in x200 µA/V scaling
XX.XX mA in x2 mA/V scaling
Resistance:
XXX.X MΩ
Power:
XXXX mW in all scalings (voltage output)
XX.XX µW in x20 µA/V scaling (current output)
XXX.X mW in x200 µA/V scaling (current output)
XXXX mW in x2 mA/V scaling (current output)
Trigger Unit:
Trigger Input front panel: TTL, active high, 10 kΩ, max. 2 kHz
Trigger Input rear panel (REMOTE): TTL, active low
Push button
Trigger Output front panel: TTL, active high, 50 Ω, length: 400 µs
Offset Ranges:
Potential: ±1 V
Current: ±400 nA in x20 µA/V scaling (current output)
Current: ±4 µA in x200 µA/V scaling (current output)
Current: ±40 µA in x2 mA/V scaling (current output)
Monitors Scaling:
Potential: 100 mV/V
Resistance: 1 V/MΩ
Current (depending on mode and scaling):
1V/mA in all voltage outputs
100 mV/µA in x20 µA/V scaling (current output)
10 V/mA in x200 µA/V scaling (current output)
1 V/mA in x2 mA/V scaling (current output)
Power: 10 V/W
Last Updated on February 3, 2021
Ordering
DigiStim: 2 channel USB based multifunction waveform generator
ELP-02D: Single-cell electroporator
Last Updated on February 3, 2021