Description
Sensitive (picoampere range) current amplifier that is intended for voltammetric and amperometric measurements with carbon-fiber microelectrodes
- Low noise, works in picoampere range
- Ideally suited for recordings from single cells
- Can be operated with external waveforms for cyclic voltammetry
- Telegraph outputs for easy interfacing to data acquisition systems
- 3-electrode headstage for a floating command potential available
- Gain settings from 0.5 to 50 mV / pA in seven steps
- Precise built-in voltage source for DC amperometry (+/- 1000 mV standard, +/- 2000 mV optional)
Applications:
- Allows simultaneous electrophysiological recordings during voltammetric or amperometric investigations using headstages with differential inputs
- Can be used in scanning electrochemical microscopy
- Also suitable for lipid bilayer recordings
Use with 5 µm carbon fiber electrodes also available from npi.
Also available as 19″ rackmount device.
Last Updated on October 21, 2024
Specification
HEADSTAGE:
Input voltage range: ±1200 mV
Operating voltage: ±12 V
Enclosure: Size: 40 x 70 x 20 mm, not grounded
Mounting plate: 50 x 70 mm, not conducting
Electrode connector: BNC with driven shield
Ground connector: 1 mm connector (black)
Driven shield output: 1 mm connector (red)
Input resistance: >1013 Ω
Current range: ±20 nA
Feedback resistor: 500 MΩ
NOISE:
<1 pA
LP FILTER:
4-pole or 8-pole Bessel FILTER
6 corner frequencies: 100, 300 500, 1k, 3k, 5k Hz.
GAIN:
6-position rotary switch (x0.5, x1, x2.5, x5, x10, x25) mV / pA
VOLTAGE SOURCE:
COMMAND VOLTAGE set by 10-turn potentiometer, range: (1000 mV, polarity selectable with polarity switch (+, 0, -), display XXXX mV
OUTPUTS:
Impedance: 250 Ω
FILTERED: BNC connector, sensitivity selectable with GAIN switch, FILTERED with LP Bessel FILTER
UNFILTERED: BNC connector, sensitivity selectable with GAIN switch
INPUTS:
Resistance: 1 MΩ
COMMAND VOLTAGE:
INPUT BNC connector, sensitivity: /10, also displayed
MONITORS:
Impedance: 250 Ω
GAIN: BNC connector, 1 V per step, +1 V….+7 V
COMMAND: BNC connector, sensitivity: x10
POWER REQUIREMENTS:
115/230 V AC, 60/50 Hz, fuse 0.4/0.2 A, slow.
Last Updated on October 21, 2024
Ordering
Part no. |
Description |
VA-10M4 |
Voltammeter module with 4-pole Bessel filter for recordings with carbon fiber electrodes, width = 1 |
VA-10M8 |
Voltammeter module with 8-pole Bessel filter for recordings with carbon fiber electrodes, width = 1 |
VA-HS3 |
Differential (3-Electrode) Headstage for VA-10 Amplifier System |
VA-HS-MINI |
VA-10 MiniHeadstage with differential input, with standard cable 2.5m, D=2.3mm, w/o housing |
VA-HS4 |
4-channel Headstage for VA-10 Modular System |
VA-CFE |
Carbon fiber electrodes, 5 µm diameter, using the Anodic Electrophoretic Deposition of Paint (EDP) method |
VA-CFE-H-BNC |
CFE holder for headstages with BNC connector |
Last Updated on October 21, 2024
Downloads
Manual:
VA-10M Manual
Brochure:
VA-10M Brochure
Last Updated on October 21, 2024