Heating/Cooling In-line Perfusion Cube

  • HCPC
Add to quote list
This product is already in quote request list
Browse the list
Category: Heating / Cooling Devices Tags: electrtophysiology temperature controllers, imaging chambers, live cell imaging, live cell life support, live cell recording, low noise temperature controllers, microcubator, microscope incubation chamber, microscope stage cooling devices, microscope stage heating devices, recording chambers, solution flow cooling, solution flow heating
  • Overview
  • Specifications
  • Downloads
  • Ordering

Overview

The Heating and Cooling Perfusion Cube (HCPC) from ALA is a compact, low-volume in-line heating and cooling device made of ceramic coated aluminum. This allows direct contact with flowing solution for optimal temperature control. The HCPC is ideal for use on a microscope stage, with its optional magnetic stand (MMT-HCPC), which can easily be mounted onto the MS-Stage.

Shown: HCPC with optional MMT-HCPC.

Key Features of the HCPC include:

  • Small footprint
  • Flow rates up to 5ml/min
  • Adjustable internal volume from 100 to 200 μl
  • Built-in temperature sensor
  • Ceramic coated internal surface
  • Polyimide output tip
  • Temperature changes at 1°C/sec
  • Compatible with ALA HCT controllers & npi PTC
    controllers

Last Updated on November 7, 2024

Specifications

Weight 90g with cable
Dimensions 16mm x 20mm x 67 mm
Cable length 1.2m
Connector 8-pin DIN
Thermistor 2252 Ohms at 25°C
Max Power 21W
Resistor 10 Ohms
Max output 7V / 3A
Max temperature 75°C
Min temperature 0°C
Volume ~200ul, adjustable to 100ul
Flow rate Max ~5ml/min at 1m height gravity feed, adjustable down to 0.5ml/min

Last Updated on November 7, 2024

Downloads

HCPC Manual

HCPC Literature

Last Updated on November 7, 2024

Ordering

HCPC Heating/Cooling Perfusion Cube with built-in sensor (small volume)
MHOLD-HCPC Magnetic holder for HCPC

Last Updated on November 7, 2024

Quote List

No products in the list

Related products

  • Oval Chamber for 25mm Round #1 or #2 Cover Glass

    Select options This product has multiple variants. The options may be chosen on the product page
  • Heating/Cooling High Flow in-line Perfusion Cube

    Show Details
  • Oocyte Perfusion Chamber for Xenoplace Workstation

    Show Details
  • Cables for ALA and npi Temperature Controllers

    Show Details

Subscribe to our Newsletter


About Us

ALA Scientific Instruments, Inc. began as Adams and List Associates Ltd. in 1986.

Recent News

  • ALA is attending this year’s Society for Neuroscience
  • ALA is attending Society for NeuroScience
  • ALA is attending Biophysical Society Meeting
  • FENS FORUM 2024
  • ALA is attending Biophysical Society Meeting

Search Site

Copyright © 2025 - Ala Scientific Instruments, Inc.
  • Facebook
  • Twitter
  • Instagram
  • LinkedIn
  • Rss
Stage Mounted MicroIncubator Heat Sink for Heating and Cooling Devices
Scroll to top

This site uses cookies. By continuing to browse the site, you are agreeing to our use of cookies.

Accept settingsHide notification onlySettings

Cookie and Privacy Settings



How we use cookies

We may request cookies to be set on your device. We use cookies to let us know when you visit our websites, how you interact with us, to enrich your user experience, and to customize your relationship with our website.

Click on the different category headings to find out more. You can also change some of your preferences. Note that blocking some types of cookies may impact your experience on our websites and the services we are able to offer.

Essential Website Cookies

These cookies are strictly necessary to provide you with services available through our website and to use some of its features.

Because these cookies are strictly necessary to deliver the website, refuseing them will have impact how our site functions. You always can block or delete cookies by changing your browser settings and force blocking all cookies on this website. But this will always prompt you to accept/refuse cookies when revisiting our site.

We fully respect if you want to refuse cookies but to avoid asking you again and again kindly allow us to store a cookie for that. You are free to opt out any time or opt in for other cookies to get a better experience. If you refuse cookies we will remove all set cookies in our domain.

We provide you with a list of stored cookies on your computer in our domain so you can check what we stored. Due to security reasons we are not able to show or modify cookies from other domains. You can check these in your browser security settings.

Other external services

We also use different external services like Google Webfonts, Google Maps, and external Video providers. Since these providers may collect personal data like your IP address we allow you to block them here. Please be aware that this might heavily reduce the functionality and appearance of our site. Changes will take effect once you reload the page.

Google Webfont Settings:

Google Map Settings:

Google reCaptcha Settings:

Vimeo and Youtube video embeds:

Accept settingsHide notification only